PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05
8
Unit features
} Positive-guided relay outputs:
3 safety contacts (N/O), instantaneous
2 safety contacts (N/O), delay-on de-energisation
} Connection options for:
E-STOP pushbuttons
Safety gate limit switches
Start buttons
Light grids and safety switches with detection of shorts across contacts
} Delay time fixed or selectable
} Possible to cancel delay time
} LED display for:
Supply voltage
Switch state of the safety contacts
Start circuit
} Plug-in connection terminals (either spring-loaded terminal or screw terminal)
} See order reference for unit types
Safety features
The safety relay meets the following safety requirements:
} The circuit is redundant with built-in self-monitoring.
} The safety function remains effective in the case of a component failure.
} The correct opening and closing of the safety function relays is tested automatically in
each on-off cycle.