Function description
Operating Manual PSENvip RL D P Set
1001641-EN-09
| 44
3
Status Downward movement
Advance measuring field
touches plate (pinch point)
Foot switch 1
System-Init 0
OSSD 1
Protected field Free
Mute 1/2 1 -> 0
Dynamic muting Start
4
Status Downward movement
Tool centre point reaches
the 8 mm point
Foot switch 1
System-Init 0
OSSD 1
Protected field Free
Mute 1/2 0
Dynamic muting Active
5
Status Downward movement
Tool centre point reaches
the 6 mm point
Foot switch 1
System-Init 0
OSSD 1 -> 0
Muting of the OSSD in steps
5 to 8 in the safety system
Protected field Interrupted
Mute 1/2 0
Dynamic muting End