2 Overview
The PSENvip is a camera-based protection and measuring system (electrosensitive pro-
tective equipment) for press brakes. It consists of a transmitter and receiver. The PSENvip
monitors the detection zone between the transmitter and receiver below the moving upper
tool.
Transmitter
} Generates parallel beam
} 2 inputs for controlling the light source
Receiver
} Evaluates the light generated by the transmitter
} Display for the operating statuses and inputs
} Membrane keypad for operating the menus and for inputs
} Max. distance between transmitter and receiver: 10 m
Inputs
} 1 input for setup mode
} 1 input for signalling when the press brake is at top dead centre
} 2 inputs for controlling the protected field mode:
Protected field can be adapted to a range of bending functions: full protected field, re-
duced protected field for box bending and lower tools with back gauge
} 1 input for acknowledging the protected field mode
Outputs
} 2 output signal switching devices (OSSD) for signalling the status of the protected field
(clear or interrupted)
} 2 outputs for signalling that PSENvip is in dynamic muting
Some inputs and outputs are used for communication with the safety system during the
system status TEST:
} Register tool class on safety system
} Approve tool class for PSENvip
LED indicators for
} Status of OSSDs
Operating statuses
} Adjustment for initial commissioning
} Tool change
} Diagnostics