Function description
Operating Manual PSENvip RL D P Set
1001641-EN-09
| 46
4.7.2 System cycle for box bending press stroke
Inputs on the PSENvip receiver:
} Protected field mode 1 = 0
} Protected field mode 2 = 1
} Acknowledgement of reduced protected field = Press pushbutton and then release
1
Status Press is at top dead
centre
Foot switch 0
System-Init 1
OSSD 0
Protected field Free
Mute 1/2 0
Dynamic muting Inactive
2
Status Downward movement
Foot switch 1
System-Init 0
OSSD 1
Protected field Free
Mute 1/2 1
Dynamic muting Inactive
3
Status Downward movement
Advance measuring field
touches plate (pinch
point)
Foot switch 1
System-Init 0
OSSD 1
Protected field Free
Mute 1/2 1 -> 0
Dynamic muting Start