4
Status Downward movement
Tool centre point
reaches the 8 mm point
v > 0
KP
8 mm
Foot switch 1
System-Init 0
OSSD 1
Protected field Free
Mute 1/2 0
Dynamic muting Active
5
Status Downward movement
Tool centre point
reaches the 6 mm point
v > 0
6 mm
6 mm
Foot switch 1
System-Init 0
OSSD 1 -> 0
Muting of the OSSD in
steps 5 to 8 in the safety
system
Protected field Interrupted
Mute 1/2 0
Dynamic muting End
6
Status Downward movement
v > 0
6 mm
Foot switch 1
System-Init 0
OSSD 0
Protected field Interrupted
Mute 1/2 0
Dynamic muting Inactive