Function description
Operating Manual PSENvip RL D P Set
1001641-EN-09
| 43
} 6 mm: 6 mm point, end of dynamic muting
} PP: Pinch point
} BDC bottom dead centre
} v = 0 mm/s closing speed at top/bottom dead centre
} v > 0 mm/s downward movement
} v > 0 mm/s upward movement
} Mute 1/2: Segment switches outputs Mute 1 and Mute 2
4.7.1 System cycle for standard press stroke
Inputs on the PSENvip receiver:
} Protected field mode 1 = 0
} Protected field mode 2 = 0
} Power Off = 0
1
Status Press is at top dead centre
v = 0
TDC
Foot switch 0
System-Init 1
OSSD 0
Protected field Free
Mute 1/2 0
Dynamic muting Inactive
2
Status Downward movement
v > 0
Foot switch 1
System-Init 0
OSSD 1
Protected field Free
Mute 1/2 1
Dynamic muting Inactive