8. EACH SETTING AND ADJUSTMENT
8.1 ADJUSTMENT REQUIRED WHEN THE UNIT IS REPAIRED OR REPLACED
1. At shipment, the unit is adjusted to its best conditions. Normally, it is not necessary to readjust even if an assembly is replaced. If the
adjustment is shifted or if it becomes necessary to readjust because of part replacement, etc., perform the adjustment as described below.
2. Any value changed in Service/Factory mode will be stored in memory as soon as it is changed. Before readjustment, take note of the
original values for reference in case you need to restore the original settings.
3. Use a stable AC power supply.
Y DRIVE Assy No adjustment required
Other assemblies No adjustment required
No adjustment required
No adjustment required
POWER SUPPLY Unit
DIGITAL Assy
X DRIVE Assy No adjustment required
Refer to “8.3 HOW TO CLEAR HISTORY DATA” .
MAIN Assy (Note)
AUDIO Assy
Service Panel Assy
Refer to “8.3 HOW TO CLEAR HISTORY DATA” and
“8.4
ADJUSTMENTS WHEN THE SERVICE
PANEL
ASSY IS REPLACED”.
Writing of backup data is required.
Refer to the “8.2 BACKUP OF THE EEPROM
(DIGITAL ASSY)”.
SENSOR Assy
Writing of backup data is required.
Refer to the “8.2 BACKUP OF THE EEPROM
(DIGITAL ASSY)”.
When any of the following assemblies is replaced
Note: After replacing the MAIN Assy, be sure to perform the FINAL SETUP.
To perform the FINAL SETUP for the display main unit and module via the RS-232C connector on the
display, set the unit to Standalone Operation mode, by issuing the SYSS00 command, then issue the
FAY command then FSP command. (Common to models of any size and for any destination)
To perform the FINAL SETUP of the entire system, i.e., the display and the Media Receiver (MR),
input commands via the RS-232C connector on the MR in System Operation mode.
For details, refer to the service manual of the Media Receiver.