135
KRP-500P
5
6 7 8
5
6 7 8
A
B
C
D
E
F
Set VOL YNOFSA D to the current setting value minus 48. / [VYF ∗∗∗]
Gradually decrease the VOL YNOFSA D value until disappear the
discharge (lit cell).
The tentative setting value of VOL YNOFS3 D + current setting
value of VOL YNOFSA D must be 256 or greater.
Replacement of abnormal circuits or
re-replacement of the panel required
Replacement of abnormal circuits or
re-replacement of the panel required
No
Ye s
Tentative setting value of VOL YNOFS3 D
+ current setting value of VOL YNOFSA D
< 258?
Display RST MASK 21 (Red 1023+). / [MKR S21]
Display RST MASK 22 (Green 1023+). / [MKR S22]
No
Set VOL YNOFSA D to the current setting value plus 25. / [VYF ∗∗∗]
Determine the current VOL YNOFSA D setting value as the final value.
Ye s
Recovery flowchart (2-3)...Changing the VOL YNOFSA D setting
[From the Main flowchart (2)]
RST MASK 15 (Magenta 120)
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Replacement of abnormal circuits or
re-replacement of the panel required
No
Ye s
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
[To the Main flowchart (2)]