EasyManuals Logo

Pioneer PDP-433PU User Manual

Pioneer PDP-433PU
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #80 background imageLoading...
Page #80 background image
PDP-433PU
80
1234
1234
C
D
F
A
B
E
1 Panel microcomputer failure
2 DIGITAL-IIC communication failure
Shutdown temperature of each temperature sensor
Sensor Temp 78
3 Abnormally high temperature
Reference
Shutdown diagnosis
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
CENTE
1/13
RVers
OSD V e r s i o n
CV I C Ve r s i o n
TTXP Ve r s i on
ion
MON I TOR V e r s i o n
Mod e l S l eect inMa
Mod e l S l eectAV
Mod e l S l eect
Cent e r cuAtime
MON I T OR
RESET
RESET OFF
RESET OFF
OFF
+
0
0
4
28
F6 91 10
TTX RPG
W2 0 0 /109 0 009:12/X200/109 0 079:12/V20
061
0/109 0 109:12/
MR O DS2 0109A//010
MR M IAN 0021E
-05
-00
PANEL Ve r s i on
FLASH Ve r s ion
MON I TOR Mo d e l
Mon i t or Acu t ime 47 H 42 M
H41M16
01
Pu l se Acut ime 164
Sensore Temp
025H9//
NPIU S1GINoT
E06
E06
E04
Screen display
Condition : When a module microcomputer failed in communication
with a panel microcomputer
Results : An OSD is displayed for 30 seconds after the failure is
detected; then the power is shut down.
Possible causes
• Open/short-circuit of the communication lines in the assembly
Condition : When a module microcomputer failed in communication with
an external EEPROM or EXPANDER
Results : An OSD is displayed for 30 seconds after the failure is
detected; then the power is shut down.
Note: A DIGITAL-IIC communication failure may occur in Standby mode.
Possible causes
Open / Short-circuit of communication line in the DIGITAL VIDEO, MR
INTERFACE and AUDIO Assys
Breaking of wire between the following points:
DIGITAL VIDEO Assy (D1) SW POWER SUPPLY Module (P2)
DIGITAL VIDEO Assy (D3) MR INTERFACE Assy (R3)
MR INTERFACE Assy (R23) AUDIO Assy (A24)
System Cable
Condition : when the internal temperature of the unit becomes abnormally high
Results : An OSD is displayed for 30 seconds after the failure is detected;
then the power is shut down.
Note: If the internal temperature of the unit becomes lower while the OSD is
displayed, the unit returns to normal operation.
Possible causes if this abnormality occurs in an environment in
which the temperature is not so high
Disconnection between the DIGITAL VIDEO Assy (D18) and temperature
sensor 1 (TE1)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pioneer PDP-433PU and is the answer not in the manual?

Pioneer PDP-433PU Specifications

General IconGeneral
BrandPioneer
ModelPDP-433PU
CategoryMonitor
LanguageEnglish

Related product manuals