INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
Level 1 & 2 Password
5.8. TO ENTER PROGRAMMING LEVEL 1 (FOR THE STORE MANAGER):
Note: The factory default setting for this control does not require an operator password to be entered.
However, the operator password requirement and value may be changed in (See section 4.12 “To Enter
Programming Level 2” (For the Store Manager). This text assumes the operator password is disabled.
Entry of a password when NOT required will not interfere with the programming process.
With no cook timers running, displays will show one of the following displays: [HEATING], [MELT]
[LIQUID (or SOLID)], or [READY].
Press the [P] program key. Left display will show
[PROGRAM]. Right display will be blank.
Enter password 6684 using the product keys as numeric
keypad for entry.
Display still shows [PROGRAM].
From the [PROGRAM] display, continue with this section or go to section 3.
5.9. TO SET COOK TEMPERATURE:
Press “P” key then press the thermometer key once for Single Vat (left side of Dual Vat) or
press key twice for Dual Vat (right side of Dual Vat).
The display will show [SET xxxF] [TEMP] or [SET xxxC] [TEMP], where “xxx” is the temperature
setting. Use the product keys for numeric entry to adjust the current setting. Press the [P] key
to save setting. Display now shows [PROGRAM]. To exit here, press [P] again, or continue.
5.10. TO CHANGE A PRODUCT KEYCOOK, SHAKE, HOLD, AND HOLD PRE-ALARM TIMES:
For each product key, Cook, Shake, Hold, and Hold Pre-alarm times are set in this section. With display
showing [PROGRAM], continue with the following section for each product key to change.
5.10.1. COOK TIME
Cook Time may be set for each product key. To deactivate any product key enter a zero value
for cook time.
Press the [Clock] key. Display will show [SELECT] [PRODUCT]. Press the desired product key
to change.
The display is now showing [nCK mm:ss] [TIME] where “n” is the key number,
“CK” means Cook, and “mm:ss” is minutes and seconds. Use the product
keys for numeric entry to adjust the current setting. Press the [Clock] key to
save cook time and continue setup for this product key.
5.10.2. SHAKE TIME
Shake time is an alarm that sounds during Cook Time to prompt operators to shake the basket.
Default for this value is zero, meaning the Shake Time is inactive. To use Shake Time, time value
must be a non-zero value, and must be set to a value less than cook time.
Display shows [nSH mm:ss] [TIME] where “n” is the key number, “SH” means
Shake, and “mm:ss” is time in minutes and seconds.
Use the product keys for numeric entry to adjust the current setting. Press the
[Clock] key to save shake time and continue setup for this product key.
Note: Cook Time minus DisplayShake Time = Shake Value Entry, Example: 3:00 cook time with a
2:00 shake time, the value you enter would be 1:00 minute.
5.10.3. HOLD TIME
Cooked product may stand in holding bins for a period of time. This timer produces an alarm to
inform operators to discard old product and start a new cook. Default for this
value is zero, meaning the Hold Time is inactive.
Display is showing [nHD mm:ss] [TIME], where “n” is the key number, “HD
means HOLD, and “mm:ss” is minutes and seconds.
Use the product keys for numeric entry to adjust the current setting. Press the [Clock] key to
save hold time and continue setup for this product key.
L20-407 rev. 2 (12/14) 21