5.10.4. HOLD PRE-ALARM
Hold Pre-Alarm is a timer setting that is used to warn operators that the Hold Time is about to
expire. To use Hold Pre-Alarm, time value must be a non-zero value, and must be set to a value
less than Hold Time. Default value is zero, meaning the Hold Pre-Alarm is inactive.
Display is showing [nPA mm:ss] [TIME] where “n” is the key number, PA means Pre-Alarm, and
“mm:ss” is minutes and seconds.
Use the product keys for numeric entry to adjust the current setting.
Press the [Clock] key to save cook time and continue setup for this product key.
Note: Value entered for Hold pre-alarm time is the hold time minus the pre-
alarm time. Example: 15:00 hold time with a 5:00 prealarm time, the value you
enter would be 10:00 minutes.
Display will again return to [SELECT] [TIME]. Repeat steps from 1 to make changes to any other
product keys or continue.
5.11. TO EXIT LEVEL 1 PROGRAMMING:
Display shows [SELECT] [TIME]. Continue to make changes or exit here in next step.
Press the [P] key.
Display shows [PROGRAM].
To exit Level 1 programming, press the [P] key again.
Displays will show [HEATING], [MELT] [LIQUID (or SOLID)], or [READY].
5.12. TO ENTER PROGRAMMING LEVEL 2 (FOR THE STORE MANAGER)
The display must show [PROGRAM] from (See section 4.8 “To Enter Programming
Level 1” (For the Store Manager). to change these options. When the product key
[0] is pressed, the display will show [SELECT] [OPTIONS]. Indicator lights above
product keys will illuminate to represent options that may be changed. Each option
listed below uses the product key [0] to toggle or scroll through available choices in
the display. When the correct value is displayed, press the [P] key to save choice. The display
will again return
to [PROGRAM] for another option selection.
5.13. FAHRENHEIT OR CELSIUS DISPLAY:
The Controller will display temperatures in the Fahrenheit or Celsius scales. The
default scale is °F. With display showing [PROGRAM], press the product key [0].
Display shows [SELECT] [OPTIONS].
Press product key 1, display shows [DEGREE n] [F OR C], where “n” is the current
setting.
Use the product key [0] to scroll through choices (F or C). Press [P] key to save choice.
Display shows [PROGRAM].
5.14. PASSWORD CHANGE OR REQUIRED?
With factory settings, an operator password is not required to enter programming Levels 1 and 2.
The password may be activated or changed in this section.
With display showing [PROGRAM], press the product key [0]. Display will show
[SELECT] [OPTIONS].
Press product key 2, display shows [SET PASS] [NEW PASS]. Use the product key
[0] to scroll through choices [NO PASS] or [PASS REQ]. Press [P] key to save
choice.
If [NO PASS] is selected Display returns to [PROGRAM].
If [PASS REQ]. is selected, display will show [PASSnnnn] [NEW PASS] to prompt for new
password. Displayed value “nnnn” is the current password. Use the product keys for
numeric entry to change password. Press [P] key to save choice. Display shows
[PROGRAM].
Note: The factory default password (6684) will always work even if a different password is selected
above.
22
L20-407 rev.2 (12/14)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pitco SSHLV14 Series and is the answer not in the manual?

Pitco SSHLV14 Series Specifications

General IconGeneral
BrandPitco
ModelSSHLV14 Series
CategoryFryer
LanguageEnglish

Related product manuals