9.4.5. GAS COMBUSTION SYSTEM
Check for gas leaks.
Check and clean vent tube on gas valve pressure regulator.
Check burners, clean debris and grease from pilot and pilot orifice tips.
Check self cleaning burner system (if equipped) that it activates when the appliance is turned
on and NOT during normal cooking & idle periods.
Check and adjust burner manifold gas pressure to nameplate reading.
Check incoming gas pressure to the appliance under static and dynamic conditions.
Check ignition system and adjust pilot flame as required.
Check flame sensor reading.
Check gap spacing and clean igniter.
Recheck for gas leaks after inspection.
9.5. VENTILATION HOOD
Proper ventilation hood operation is very important for the correct operation of this appliance and the
safety of personnel. The ventilation hood should be inspected at the time of installation of this
appliance to ensure that it will operate properly in conjunction with the appliance. A regular schedule
of examination in accordance with ANSI/NFPA 96 latest edition and/or local codes must be followed.