Telephone Line Powered Auto Dialing emFONE
Product Manual
EM-2
Copyright © 2014 Pixel Technologies Pty. Ltd
16
3.8. Remote Phone Monitoring System (RPMS)
RPMS is an auto self-test and health check feature designed to report system status to a remote
communication centre.
3.8.1. Reporting Conditions
The unit will make a health check report when the following conditions are valid:
After an alarm call has been raised.
When a manual report is initiated.
Automatically as per the periodic report specified in section 3.8.3.
3.8.2. RPMS Enable
By default RPMS is disabled. To enable the feature enter the following sequence:
#
PIN
9
#
7
A
*
Setting
Formula
Minimum
Maximum
Default Value
A
RPMS Enable
0 = Disable 1 = Enable
0
1
0
Table 5 - RPMS Settings
To hear an audible playback of the RPMS enable settings, enter the following sequence:
*
#
7
3.8.3. Periodic Reports
Enter the sequence below to set the frequency of which the unit will perform an auto self-test report:
#
PIN
2
#
7
N
N
*
Setting
Minimum (Days)
Maximum (Days)
Default Value (Days)
NN
RPMS Enable
01
30
03
Table 6 - RPMS Settings
To hear an audible playback of the periodic reports settings, enter the following sequence:
#
0
7
*
3.9. Reset to Factory Default
To reset programmable setting to factory default, press and hold the ‘0’ key for 3 seconds until 4
audible beeps are heard then enter;
#
*
NOTE: This feature does not revert the voice identification recording and RPMS programmed values
to the factory default settings.