ATR 421 - User manual 39
28 d.i.c.t. Digital Input Contact Type:
o.c. (Open Contact)
c. c. (Contact closed) > Default
29 ui . d . 2 Visualization Display 2: Set visualization on display 2 during a
cycle.
e.st.s. (End Step Setpoint) Operating step end temperature
r. s p u (Real Setpoint) Updated according to the selected gradient
cY.nu. (Cycle Number) Number of operating cycle. > Default.
st.nu. (Step Number) Number of operating step
ti m e Time elaplsed from cycle start
out.p. (Output Percentage)
30 de.st. Delaied Start: Enables initial waiting for delayed start of cycle.
di s . (Disabled) Initial waiting disabled. > Default.
en. (Enabled) Initial waiting selectable by the user.
31 s.spu Starting Setpoint: Enables cycle starting setpoint to guarantee
the programmed gradient for the  rst step.
di s . (Disabled) Cycle starting setpoint disabled. > Default.
en. (Enabled) Cycle starting setpoint selectable by the user.
en.a.t. (Enabled Ambient Temperature) Fixed cycle starting setpoint
(25°C for temperature sensors and 0 for linear sensors).
32 sp.fu. Special Functions: Enables simple thermoregulator function
and manual setting of output percentage.
di s . (Disabled) No function available. > Default.
tHer. (Thermoregulator) Enables simple thermoregulator function.
man. (Manual) Enables manual mode.
tH. m a . (Thermoregulator and Manual) Enables both simple
thermoregulator and manual function.
33 HLd. f. Hold Function: Enables “Hold” function; allows to hold the
cycle and modify setpoint by keyboard. The same function NOT
have to be enabled on Par. 27 dGt.i.
di s . (Disabled) “Hold” function disabled. > Default.
en. (Enabled) “Hold” function enabled.