Timeout For Answer
To configure Outgoing call, Incoming call, default is 60s, (30-120s)
Hang Up After RTP Time
Out
To configure RTP Time out interval, Door phone will hang out if not
receive command when RTP time out, default is 10s, (5-60s)
Call Button To configure call button feature.
Call Button Selection: can choose 2 call buttons.
Call Key Night: Enable or Disable night call key.
Call Button Day1/2/3: replace a phone number you want in Bright Day
Call Button Night: replace a phone number you want in Dark Day
Round Robbin Time Out: Hang Out Time Interval, for example, if Call
Button Day 1 hang out, it will go to Call Button Day 2, call button day 2
hang out, then go to Call Button Day 3
Day Night Setting Set the start of day time and night time
Day Start: Starting point of daytime
Night Start: Starting point of night time
Key Pad Light and Call Button Selection configures are based on this
Day Night Setting feature.
Security Staff Button To configure call phone number to security staff.
Max. Call Duration To configure the longest talk time, it will automatically hang up after a
limited time (time range is 0~ 30 minutes). 0 minute means it will not
automatically hang up.
Local RTP To configure local RTP port range, including min. RTP ports and max.
RTP ports (1024- 65535)
Hang Up After Opening
Door
To configure duration for the hang up after opening the door, default is
15s, (0-15s). 0 means to hang up immediately after opening the door.
Web Call To configure a call from web.