ELECTRICAL
10.9
CRANKING OUTPUT TEST WITH PEAK READING VOLTMETER
Thefollowingpeakvoltagetestswillmeasuretheamountofoutput directlyfrom eachcomponent. Apeakreading
voltmeter must be used to perform the tests
. A variety of peak reading adaptors are commercially available for
use with the Fluke ™ 73 Digital Multitester, Tektronix DMM155, and other digital VOMs which will allow peak volt-
age tests to be performed accurately. Follow the directions provided with the adaptor . All measurements are
indicated in DC Volts. Readings obtained without a peak reading adaptor will be significantly different.
Disconnect the stator connectors from the CDI module. Test output from exciter coil, pulse (trigger) coil, and
comparetothechart. Thefollowingmeasurements areobtainedwhencranking theenginewiththe electricstart-
er, spark plug installed. The starter system must be in good condition and the battery fully charged.
200 W att 4 Stroke (Sportsman 400)
Coil
Connect Meter
Wires To:
Reading
(With Peak Reading V olt meter)
Exciter 1 Black/Red and Red 140 DCV
Exciter 2 Black/Red and Green 140 DCV
Exciter 3 Green and Red 5 DCV
Pulse (T rigger) White/Red and White 2.5 DCV
250 W att 4 Stroke (Sportsman 500)
Coil
Connect Meter
Wires To:
Reading
(With Peak Reading V olt meter)
Exciter 1 Black/Red and Red 34 DCV
Pulse (T rigger) White/Red and White 3.3 DCV
CDI OUTPUT TEST USING PEAK READING ADAPTOR
Re-connectallCDIwirestostatorwires. Disconnect CDImodulewirefrom ignitioncoilprimaryterminal. Connect
onemeterleadtoenginegroundandtheothertotheignitioncoilprimary wireleadingfromtheCDImodule. Crank
engine and check output of CDI wire to coil (130 DCV). Reconnect coil wire to CDI.
Output w/ Peak output tester
130 DCV
Average Output w/ Digital Voltmeter
20 DCV