MAINTENANCE SCHEDULE
ASP Acid Service Kit, part #55619 - replace at least every 12 months or as required
Kit includes:
– Peristaltic Pump Squeeze Tube and Rollers
– Fume Stop Cap (to suit 15L or 20L Acid Drums)
– Injection Point non-return valve
– Acid Feed Tubing
– Tubing weight
Peristaltic Pump Maintenance
Check regularly for signs of wear or leakage, and replace the peristaltic pump
squeeze tube and rollers at least every 12 months.
The Pool Lab ASP peristaltic acid pump is fitted with a santoprene squeeze tube which is
suitable for 16.5% Hydrochloric Acid.
A split or leaking tube may be dangerous to persons and may cause damage to
surrounding property or equipment.
Pro-active maintenance will ensure trouble free operation and peace of mind.
It is recommended that an authorised service person perform this maintenance, however
the home owner or user may also perform this procedure if all safety precautions are
undertaken and they have some basic DIY skills.
Follow instructions included in the kit: ASP Acid Service Kit, part #55619
✗ DO NOT allow children or unqualified persons to operate or perform any
maintenance on this device
✗ DO NOT allow children, unqualified persons or animals access to the chemical
dosing equipment, storage drums, feed tubes, chemical pumps or injection point
✗ DO NOT use acid stronger than 16.5%, or acid that is not labelled as Hydrochloric
or Muriatic Acid
✗ DO NOT allow acid to come in contact with chlorine, or any other alkalis
✗ DO NOT use non-genuine parts or fittings
✔ ALWAYS use protective eye wear, gloves suitable for acid, and a suitable respirator
while servicing the acid dosing system. (Type E respirator)
✔ ALWAYS ensure acid feed tubing is correctly and neatly installed
✔ ALWAYS flush acid dosing system with fresh water before servicing
19