ACID DOSING SYSTEM
The peristaltic acid pump can be mounted directly to the side of the chlorinator cell or
alternatively it can be mounted on nearby vertical pipework. Use the heavy duty cable tie
provided (or a suitable gear clamp) to secure the pump in position.
Step 1. Mount the peristaltic pump
assembly as shown, or to a nearby vertical
pipe. Remove the injector port blanking
plug from the cell housing.
Step 2. Install the Acid Injector. Ensure the
o-ring is in place, and tighten by hand only.
Step 3. Install a short length of 5mm tubing
to connect the Acid Pump outlet to the Acid
Injector. Tighten lock nuts by hand to
secure tubing.
Step 4. Install the remaining 5mm tubing to
the Acid Pump inlet. Tighten lock nut by
hand to secure tubing.
Step 5. Insert loose end of 5mm tubing into
Fume Stop Cap as shown. Ensure tubing
can reach bottom of reservoir, and cut to
length if required. Fit tubing weight to
bottom end of tube.
Step 6. Fit Fume Stop Cap to Acid
reservoir, and pass through enough tubing
to reach bottom of the drum. Lightly tighten
lock nut to secure tube.
28