INSTALLATION GUIDE
The Pool Lab ASP requires a Pool Lab Salt Chlorinator (Plus or MAX model) to operate.
Install the Pool Lab Salt Chlorinator as per the Installation Guide in the Chlorinator Manual.
The following points need to be adhered to:
The ASP must be located after the filter in the water circuit
The ASP must be before the salt chlorinator cell in the water circuit
The ASP must be positioned before any heating equipment in the water circuit
The ASP must be mounted upright on horizontal pipework (as shown below)
The ASP must not be located on the suction (vacuum) side of the filtration pump
The ASP must not be located after the salt chlorinator cell in the water circuit
Pool and Spa combination systems must use a spa flow switch
Where a pool and spa combination exists a separate spa flow switch MUST be used,
otherwise the spa will not be safe to use. The spa flow switch must be installed on the spa
suction line.
NOTE: For ease and flexibility of installation the Pool Lab ASP is fitted with an internal
BI-DIRECTIONAL FLOW SWITCH. Therefore it does not matter which direction water is
flowing through the ASP unit.
NOTE: Pool Lab SPA FLOW switches are however uni-directional and therefore must be
rotated to match the direction of flow in the spa suction line.
HANDY HINT: If installing into existing pipework, cut a 230mm section from the
existing pipe. Tighten unions before glue is set to ensure an accurate fit.
25