SYSTEM CONFIGURATION
Once the Pool Lab Chlorinator has detected that the Pool Lab ASP is connected, the MAIN
MENU will have options relating to your ASP configuration and settings.
Authority Level
System configuration items are protected against accidental changes with a user
AUTHORITY level. Before you can change any system configuration items, you must first
set the AUTHORITY level to “INST” (INSTALLER).
1. Go to the MAIN MENU (press and hold VIEW for 3 seconds)
2. Navigate to SYSTEM CONFIG, and press VIEW
3. Navigate to AUTHORITY, and press VIEW
4. Press VIEW again to edit the AUTHORITY level
5. Use the UP / DOWN buttons to change the AUTHORITY level to “INST”
6. Press VIEW to save the changes
7. Press BACK at least 3 times to exit the menu system
The “INST” AUTHORITY level setting will automatically revert back to USER after 5
minutes of inactivity, or it can be changed back to USER manually.
“TECH” (Technician) authority level provides access to diagnostic tools and advanced
settings. This access level requires a PIN which is available in the PL Series Technical
Manual. Also note this authority level will not revert back to USER automatically.
“FACT” (Factory) authority level provides access to data that is used for testing and
debugging purposes. This authority level requires a PIN and should only be accessed if
you are instructed to by a qualified technician.
Pool and Spa Volumes
It is essential to set the pool and spa volumes correctly before running the Pool Lab ASP
as they are used to calculate chlorine and acid deliveries.
Set user AUTHORITY to INSTALLER before proceeding (as described above).
1. Go to the MAIN MENU (press and hold VIEW for 3 seconds)
2. Navigate to SYSTEM CONFIG, and press VIEW
3. Navigate to POOL/SPA VOLS, and press VIEW
4. Navigate to POOL VOLUME, and press VIEW to edit
(a) Use the UP and DOWN buttons to adjust the value
(b) Round the value down to the nearest 5,000 Litres
(c) If installed on a SPA ONLY system, set POOL VOLUME to ZERO
(d) Press VIEW to save the value
5. Navigate to SPA VOLUME, and press VIEW to edit
(a) Use the UP and DOWN buttons to adjust the value
(b) Round the value down to the nearest 100 Litres
(c) If installed on a POOL ONLY system, set SPA VOLUME to ZERO
(d) Press VIEW to save the value
6. Press BACK at least 3 times to exit the menu system