EasyManua.ls Logo

POOL LAB ASP PL Series - ASP Tools - Utilities; Reagents; Run Tests; Acid Prime

Default Icon
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ASP TOOLS – UTILITIES
To access the ASP TOOLS menu:
1. Go to the MAIN MENU (press and hold VIEW for 3 seconds)
2. Navigate to ASP TOOLS, and press VIEW
3. Navigate the the menu items listed below, press VIEW to select
Reagents
The reagents menu has two options:
Reagent Status, this option will show the status, OK or EMPTY for each reagent.
Prime Reagents, this option will allow you to force a prime cycle. All three reagents
will attempt to prime after selecting this option.
Run Tests
The RUN TESTS view allows you to manually trigger a test cycle without the system
delivering any chlorine or acid after the test. When a test is triggered manually, the test
timer will also be reset. The results of this test will be shown in view “HOME” after the test
has completed/
Run Tests & Deliveries
The RUN TESTS & DELIVERIES view allows you to manually trigger water tests and the
system will dose with chlorine and acid as required. When a test is triggered manually, the
test timer will also be reset. Chlorine and acid deliveries may or may not occur after this
test depending on the test results and the chlorine and pH target settings.
Acid Prime
The ACID PRIME view allows you to manually run the acid delivery pump. This is useful
for testing, or when the acid line is not primed. The ACID PRIME view also has a
secondary function when the ACID FEED is PAUSED it can be used to cancel the
PAUSED state, and resume acid feeding.
24