“ACID FEED xxx mL/L”
Acid dosing is in progress.
Approximate delivery
amount remaining is shown.
No action required.
Acid feed should only occur
while the filter pump is
running, otherwise you may
need to consult an approved
service agent.
Display Message:
“pH NOT AT TARGET”
“CHECK ACID FEED”
The ASP has detected the
pH has not reached the set
target value for over 72
hours.
Check acid reservoir, and fill
or replace if required.
Check acid pump and feed.
Use the ACID PRIME
function from the ASP
TOOLS menu to test the
acid pump.
Display Message:
“LOW CHLORINE”
The ASP has detected a low
chlorine level <1.0ppm for
over 72 hours.
If bather load has been high
then you may need to bolster
the chlorine residual with the
addition of liquid chlorine.
Have water tested
professionally to determine if
the pool requires a shock
dose of chlorine.
For outdoor pools reduce
chlorine demand with the
use of pool covers, and
stabilizer (cyanuric acid).
Display Message:
“CALIBRATE ERROR”
The ASP could not calibrate
to clear water, or could not
acquire a water sample.
Consult an approved service
agent.
30