Function Prog.
no.
Level
1)
Standard value
Operation HC2
Commonly with HC1 | Independently
44 C Commonly with HC1
Operation HC3/P
Commonly with HC1 | Independently
46 C Commonly with HC1
Room temperature Unit 1
Only for Heating circuit 1 | For all assigned heating circuits
This parameter is only visible in the room device!
47 C For all assigned heating
circuits
Presence key device 1
None | Only for Heating circuit 1 | For all assigned heating circuits
This parameter is only visible in the room device!
48 C For all assigned heating
circuits
Readjustment room sensor
This parameter is only visible in the room device!
54 E 0.0°C
Software version 70 E -
Radio
Parameter only visible, if wireless room device exists!
Room unit 1
Missing | Ready | No reception | Change battery | Delete device
130 C missing
Room device 2
Missing | Ready | No reception | Change battery | Delete device
131 C missing
Room unit 3
Missing | Ready | No reception | Change battery | Delete device
132 C missing
Outside sensor
Missing | Ready | No reception | Change battery | Delete device
133 C missing
Repeater
Missing | Ready | No reception | Change battery | Delete device
134 C missing
Operator unit 1
Missing | Ready | No reception | Change battery | Delete device
135 C missing
Operator unit 2
Missing | Ready | No reception | Change battery | Delete device
136 C missing
Operator unit 3
Missing | Ready | No reception | Change battery | Delete device
137 C missing
Service unit
Missing | Ready | No reception | Change battery | Delete device
138 C missing
Delete all devices
No | Yes
140 C No
Time prog heating circuit 1
Preselection Mo - Su
Mo-Su | Mo-Fr | Sa-Su | Mo | Tu | We | Th | Fr | Sa | Su
500 Eu Mo
1st phase on 501 Eu 06:00 (h/min)
1st phase off 502 Eu 22:00 (h/min)
2nd phase on 503 Eu --:-- (h/min)
2nd phase off 504 Eu --:-- (h/min)
3rd phase on 505 Eu --:-- (h/min)
3rd phase off 506 Eu --:-- (h/min)
Copy? 515 Eu
Programming
52 Paramount three 30-115 kW 7308272-03 03.14