8.3 Setting table
- Not all parameters displayed in the display are listed in the setting table.
- Depending on the plant configuration, not all parameters listed in the setting ta-
ble are displayed in the display.
- In order to get to the setting levels: Enduser (Eu), Commissioning (C) and Engi-
neer (E), press OK button; after this, press and hold the information (i) button for
3 seconds, select the required level with the rotating knob and acknowledge
with the OK button.
Tab. 9: Setting the parameters
Function Prog.
no.
Level
1)
Standard value
Time of day and date
Hours / minutes 1 Eu 00:00 (h:min)
Day/month 2 Eu 01.01 (day. month)
Year 3 Eu 2030 (year)
Start of summertime 5 E 25.03 (day.month)
End of summertime 6 E 25.10 (day, month)
Programming unit
This parameter is only visible in the room device!
Language 20 Eu English
Info
Temporarily | Permanently
22 E Temporarily
Contrast of display 25 E
Operation lock
Off | On
26 E Off
Programming lock
Off | On
27 E Off
Units
°C, bar | °F, PSI
29 Eu °C, bar
Save basic settings
No | Yes
This parameter is only visible in the room device!
30 E No
Activate basic settings
No | Yes
This parameter is only visible if a suitable standard setting is
available in the programming unit.
31 E No
Use as
Room unit 1 | Room unit 2 | Room unit 3/P | Operator unit 1 | Opera-
tor unit 2 | Operator unit 3 | Service unit
This parameter is only visible in the room device!
40 C Room controller 1
Room controller 1 assignment
Heating circuit 1 | Heating circuits 1 and 2 | Heating circuits 1 and 3/P
| All heating circuits
This parameter is only visible in the room device, as the operating
unit in the boiler is fixed programmed for the operating device!
42 C Heating circuit 1
Programming
7308272-03 03.14 Paramount three 30-115 kW 51