VPx Range Users, Installation & Servicing Instructions Doc Ref M205 issue 1.2 Nov 2018.
Note: The limit thermostat(s) can only be reset
once the unit has cooled down. Unless the
cause of the fault condition is readily obvious,
for example a power cut whilst the heater was
operating, a service engineer should be contacted.
E) Maintenance
To maintain efficient, reliable and safe operation of the
heater it must serviced annually by a qualified person.
F) IMPORTANT
Free access must be maintained to and around the heater
for servicing purposes and the air supply to the heater
must not be restricted in any way. Combustible materials
must not be stored adjacent to the heater.
If at any time a gas leak is suspected, turn OFF the gas
supply at the meter and contact the local gas undertaking
immediately.
All Powrmatic heaters use gas and electricity to power
them, they may also contain moving parts such as pulleys
and belts. It would be hazardous to tamper with or
attempt to service unless you are a competent person in
the field of Gas and Electrical work.
If you have any safety questions reference the servicing
and installation of any of our heaters please do not
hesitate to contact our head office for expert advice. Your
safety is paramount to us.
Gas Safety (Installation & Use) (Amendment)
Regulations 2018
It is law that all gas appliances are installed,
adjusted and, if necessary, converted by
qualified persons* in accordance with the
current issue of the above regulations.
Failure to install appliances correctly can lead to
prosecution. It is in your own interests and that of safety
to ensure that the law is complied with.
* Gas Safe Registered Engineer
The VPx range are highly efficient, gas fired, fanned
circulation air heaters that cover heat outputs of 35kW to
140kW, have a closed combustion circuit and are supplied
complete with a flue system that can be either vertical or
horizontal.
VPx heaters are certified for use on Natural Gas, Group H
- G20*. Appliance Categories are Cat II2H (GB, IE). All VPx
heaters are CE certified and conform to all the European
directives stated in section 1.3.1
VPx heaters are designed to be floor standing and have a
centrifugal fan assembly fitted at the base of the heater
to circulate the air being heated past the formed tube
heat exchanger.
VPx heaters feature a closed combustion circuit and have
an internal exhaust fan, mounted downstream of the
heat exchanger, to evacuate the products of combustion
and draw in air for combustion. The air heater must be
connected to a flue system that is approved by Powrmatic
Ltd.
The heaters intended primarily for heating commercial
or industrial premises. They must not be used where the
atmosphere inside the premises could be contaminated
e.g. Dust, oil mist etc. or in areas classified as hazardous
as defined in BS 5345: Part 2. They are not suitable for
siting externally.
Heaters are fitted as standard with inshot burners, a fully
automatic control for ignition, flame sensing, gas supply
control and safety functions, an internal exhaust fan,
main air fan, fan command module and a limit thermostat.
Options include Modulating burner controls, inlet duct
connection, outlet duct connection, 90° outlet bend and a
full range of modular duct components.
IMPORTANT
Service and Maintenance Engineers shall
ensure that replacement items are fitted,
adjusted and set in accordance with the
data and detail set out in these instructions. If in doubt
consult Powrmatic Technical Department.
* LPG conversion kits available.
1.1 Introduction
User Instructions