Do you have a question about the Powrmatic LX Series and is the answer not in the manual?
Provides an overview of the LX range and its features.
Details physical measurements of various LX models for installation planning.
Describes available flue systems and components for safe exhaust.
Lists available accessories and optional configurations for the LX units.
Presents key performance specifications, outputs, and electrical data for LX models.
Specifies suitable and unsuitable installation locations for safety and performance.
Details requirements for connecting the heater to the mains power supply.
Outlines requirements for installing approved flue systems and combustion air.
Covers requirements for the gas supply connection, pressure, and safety.
Specifies ventilation needs based on installation type and room conditions.
Information on assembling standard LX heater configurations.
Instructions for attaching the optional fan plenum box accessory.
Instructions for attaching the optional fan mixing box accessory.
Details minimum clearances around the heater for installation.
Explains methods for securely suspending the heater unit.
Step-by-step guide for making the final gas connection.
Instructions for making the final electrical connections to the heater.
General guidelines for installing flue systems and combustion air.
Describes how to properly join flue system components using locking bands.
Detailed installation steps for vertical balanced flue systems.
Detailed installation steps for horizontal balanced flue systems.
Guidance on installing condensate drains for vertical flues.
Identifies the location and function of the gas valve.
Locates and identifies the main control board for diagnostics.
Shows the location of the high limit reset button for safety.
Details the process of making external electrical connections to the heater.
Illustrates a typical wiring setup with an MC200 controller.
Explains wiring requirements for external controls like thermostats.
Lists fuse ratings and part numbers for electrical protection.
Provides the internal wiring diagram for specific LX F and C models.
Shows the internal wiring diagram for LX C35-140 models.
Wiring details for axial fans in specific LX F models.
Wiring details for axial fans in larger LX F models.
Preliminary checks to ensure safe operation before initial lighting.
Step-by-step guide for starting and running the air heater.
Procedure for checking and adjusting burner gas pressures.
Details how to check and set the limit thermostat settings.
Instructions for safely removing the main burner assembly for maintenance.
Guidance on inspecting and maintaining ignition and flame sensors.
Procedures for inspecting and cleaning the heat exchanger.
General guidance on replacing faulty components with genuine parts.
Steps for replacing the gas valve assembly.
Procedure for replacing air pressure switches.
Explains error codes indicated by the heater's LED light.
Describes status indications on the R2R main control board.
Provides a step-by-step troubleshooting flowchart for common issues.
Lists part numbers for the R2R control board for different kW sizes.
Identifies part numbers for the main air fan in LX F models.
Lists part numbers for centrifugal blowers in LX CCF models.
Provides data related to ecodesign requirements for energy efficiency.