Procedure 5.5 - Troubleshooting the Lift System
Lift System Description:
The lift system on these units consists of an AC line voltage driven lift motor (120 Vac), and an
internal 1 Kpotentiometer for lift position identification. The lift motor contains two motor
windings, one to operate the motor in an “upward” direction and the other to operate the motor in
a “downward” direction. As the lift motor is operated, the motor also rotates the potentiometer via
an internal gear system. Therefore, the position of the lift system can be determined by
monitoring the value of the internal potentiometer. The lift motor is initially set at a known starting
position (calibration, See Procedure 4.1), subsequent motor movement is tracked via the
potentiometer resistance reading.
Note:
All resistance measurements must be performed with power removed from the treadmill.
Performing resistance measurements with voltage applied may damage your ohmmeter.
Procedure
1. If the lift motor operates but creates a lift error (error 40 or 42) go to step 16. If the lift motor
will not move continue with step 2.
2. Set the treadmill’s circuit breaker in the “off” position and remove the AC line cord from the
AC outlet.
3. Remove the F2 (Lift AC) fuse from the lower PCA. Using an ohmmeter, check the resistance
of the F2 fuse. See Diagram 5.2. The fuse should measure approximately 0.1 or less. If
the fuse is open or high resistance, replace the fuse.
Diagram 5.2 - Lower PCA
Fuse F2
J1 Connector
J7 Connector
J3 Connector

Other manuals for Precor C966

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor C966 and is the answer not in the manual?

Precor C966 Specifications

Power IconPower
motor4.0 hp continuous duty
power at 120 V120 v @ 50/60Hz 20 Amps
power at 240 V240v @ 50/60Hz 20 Amps
Performance IconPerformance
speed0.5 to 16 mph (1 to 26 kph)
incline- 3% to 15% grade
framePowder-coated steel
Weight and Dimensions IconWeight and Dimensions
length86 inches (218 cm)
width with handrails37 inches (93 cm)
width without handrails34 inches (86 cm)
height59 inches (150 cm)
weight375 lbs (170 kg)
shipping weight470 lbs (213 kg)
running surface60 inches x 20 inches (153 cm x 51 cm)