Procedure 6.10 — Replacing the Lower PCA
1. Set the treadmill circuit breaker in the “off” position. Remove the AC line cord from the AC
outlet.
2. Note the routing and tie down points of all of the wiring coming into the lower PCA. This
information will be required after the replacement lower PCA has been installed. It is
important to have the cabling correctly routed and tied down.
Diagram 6.10 — Lower PCA Mounting
3. Remove the two bolts that fasten the lower PCA to the frame. Remove the lower PCA.
4. Set the replacement lower PCA at its mounting position and fasten it with the bolts removed
in step 3.
5. Re-connect and cable tie all of the lower PCA wiring as noted in step 2.
6. Set the treadmill circuit breaker in the “on” position and check treadmill operation per
Procedure 3.

Other manuals for Precor C966

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor C966 and is the answer not in the manual?

Precor C966 Specifications

Power IconPower
motor4.0 hp continuous duty
power at 120 V120 v @ 50/60Hz 20 Amps
power at 240 V240v @ 50/60Hz 20 Amps
Performance IconPerformance
speed0.5 to 16 mph (1 to 26 kph)
incline- 3% to 15% grade
framePowder-coated steel
Weight and Dimensions IconWeight and Dimensions
length86 inches (218 cm)
width with handrails37 inches (93 cm)
width without handrails34 inches (86 cm)
height59 inches (150 cm)
weight375 lbs (170 kg)
shipping weight470 lbs (213 kg)
running surface60 inches x 20 inches (153 cm x 51 cm)