Procedure 2.2 — Displaying Information
The information display will access the following data;
Odometer
Hour meter
Software version
Error log
Serial Number
Procedure
1. Plug the power cord into the wall outlet, then turn on the treadmill with the circuit breaker.
2. With the PRECOR banner scrolling, press the keys RESET,6,5, sequentially. The odometer
display will be initiated.
3. The treadmill’s odometer will be displayed as 1234567 MPH or 1234567 KPH depending on
club settings (See Procedure 2.3).
Note: The odometer data is stored in non-volatile memory on the upper PCA. If the upper PCA
is replaced the odometer data will be lost.
4. Press the STOP or the ENTER key to proceed to the hour meter display.'
5. The operating time of the unit will be displayed as 12345 HOURS. The operating time is
defined as total amount of time that the unit has operated in program modes with the drive
motor running. The hour meter is also used to provide the “time stamp” for the error code
log.
6. Press the STOP or the ENTER key to proceed to the software version display.
7. The software versions of the upper and lower PCA’s will be displayed as;
UPPER X.XX LOWER X.XX
8. Press the STOP or the ENTER key to proceed to the error log.
9. The error log will store up to 10 error conditions. The errors are logged with the most recent
error in position one. When a new error condition occurs, each existing error is pushed down
one position in log. If there was an error in position 10 when a new error was logged, the
error that was in position 10 will be lost.
10. Each error in the log will show the odometer reading (in miles) and the time (hour meter)
when the error occurred. The errors are displayed as;
1 ER20 1234567 MI 12345 HRS.

Other manuals for Precor C966

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor C966 and is the answer not in the manual?

Precor C966 Specifications

Power IconPower
motor4.0 hp continuous duty
power at 120 V120 v @ 50/60Hz 20 Amps
power at 240 V240v @ 50/60Hz 20 Amps
Performance IconPerformance
speed0.5 to 16 mph (1 to 26 kph)
incline- 3% to 15% grade
framePowder-coated steel
Weight and Dimensions IconWeight and Dimensions
length86 inches (218 cm)
width with handrails37 inches (93 cm)
width without handrails34 inches (86 cm)
height59 inches (150 cm)
weight375 lbs (170 kg)
shipping weight470 lbs (213 kg)
running surface60 inches x 20 inches (153 cm x 51 cm)