5. Plug
1
in the power cord and switch the power ON.
6. Wait for the console to power up and then clear the Error Log as follows:
On LED P10, P30, P30i and P31 consoles
a. Clear the Error Log of any stored error codes: Hold down PAUSE to access the
Error Log > select OK to view error codes, and then hold down QUICK START
to clear the Error Log of all error codes.
On touchscreen P62, P80, and P82 consoles
a. Access the service Settings menu (51765761), select About > CPA Event
Log. Then select the CLEAR softkey to clear the CPA Event Log.
b. Exit and return to the “Welcome” banner home page, select the Back softkey.
7. Reinstall the hood cover, see "Hood Cover Replacement" on page 82.
8. Do the machine Operation Verification tests (see "Operation Verification" on page 23)
and return to service.
1
Device power cord connector or electrical cable male connector that is inserted into an
electrical receptacle "outlet" (also called the plug-in).
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 119
6 Replacement Procedures
Motor Controller (MC) Replacement