7.2. Key associated functions
When the different buttons are pressed, the functions described modify the machine
conditions.
Button
Machine status
Display
Action
Select
Programme selection
P01
Switches to temperature selection
Temperature selection
60º
Switches to humidity selection
Humidity selection
%20RH
Switches to programme selection
While operating.
Temperature selection
60º
Switches to humidity selection
While operating.
Humidity selection
20%RH
Switches to temperature selection
In case of alarm
AL-X
Reset alarm
Arrows
Programme selection
P01
Increase / Decrease Programme No.
Temperature selection
60º
Increase / Decrease temperature
Humidity selection
%X
Increase / Decrease humidity
Start/Stop
Programme selection
P01
Start the cycle with the last selected parameters
Humidity selection
%20RH
Start the cycle with the last selected parameters
Temperature selection
60º
Start the cycle with the last selected parameters
Operating
For the selected programme
In case of alarm
AL-X
Reset alarm
Prog. (x3)
Machine stopped
Enters programming mode
7.3. Information displayed
The display offers different types of information, including the programme number, the time
remaining, the percentage humidity and the temperature setting. The information may vary
according to the state of the machine at any moment.
When the machine is operating, the % symbol flashes.
When the heating is ON, an arrow pointing upwards appears next to the thermometer.
The following table shows all the possible information displays and the conditions in which
they are displayed.
Display
Machine status
Comments
MP
In the ignition (2s)
Shows software version
END
End / Anti-crease
End of cycle / anti-crease cycle
(2)
AL-X
Alarm
Displays one of the alarms, see section 5
(2) The End / Anti-crease cycle lasts a maximum of 99 minutes. During this period, an alarm
will sound every three minutes, reminding you that the cycle has finished. After 99 minutes
the machine returns to the status: Pause.

Table of Contents