81
3.4. Electrical connection
Make sure that the characteristics of the available power supply correspond to those of your dryer,
indicated on its identification plate, and that the cable section and other line accessories can
supply the necessary power.
The machine leaves the factor with the complete electrical installation, and therefore you will
only have to remove the cover on the back of the dryer and connect each of the terminals to the
three phases L1, L2, L3 and neutral N to the terminals of the general switch.
It is COMPULSORY to insert a circuit breaker and differential switch between the wiring and the
mains, and the sensitivity of the differential switch must be 300 mA. Higher sensitivity, for
example 30 mA, common in domestic installations may cause operating anomalies in the
machine.
Connect the three phases, neutral in the general switch and the protection cable to earth on the
electrical components panel according to the following table (section in mm
2
).
Correct earthing is essential to guarantee the safety of users and correct
operation.
DS/DL-11
DS/DL-17
DS/DL-23
STANDARD
EXCELLEN
CE
STANDARD
EXCELLEN
CE
STANDARD
EXCELLEN
CE
Voltage and Standard Wiring
V
230I(CG,CV
)-
400VIII+N+
G(CE)
230I(CG,CV
)-
400VIII+N+
G(CE)
230I(CG,CV
)-
400VIII+N+
G(CE)
230I(CG,CV
)-
400VIII+N+
G(CE)
230I(CG,CV
)-
400VIII+N+
G(CE
230I(CG,CV
)-
400VIII+N+
G(CE
Frequency
Hz
50 / 60 (3)
50 / 60 (4)
50 / 60 (3)
50 / 60 (4)
50 / 60 (4)
50 / 60 (4)
Electrical
Heating
Cable Section 230 I + T
/Fuse
Nº x mm2 / A
3 x 35 / 63
3 x 35 / 63
-
-
-
-
Cable Section 230 III
+T/Fuse
Nº x mm2 / A
4 x 10 / 40
4 x 10 / 40
4 x 16 / 63
4 x 16 / 63
4 x 25 / 80
4 x 25 / 80
Cable Section 400 III + N +
T / Fuse
Nº x mm2 / A
5 x 4 / 25
5 x 4 / 25
5 x 10 / 32
5 x 10 / 32
5 x 10 / 40
5 x 10 / 40
Gas or Steam
Heating
Cable Section 230 I + T/
Fuse
Nº x mm2 / A
3 x 1,5 / 20
3 x 1,5 / 20
3 x 1,5 / 20
3 x 1,5 / 20
3 x 1.5 / 20
3 x 1.5 / 20
Cable Section 230 III +
/Fuse
Nº x mm2 / A
4 x 1,5 / 20
4 x 1,5 / 20
4 x 1,5 / 20
4 x 1,5 / 20
4 x 1,5 / 20
4 x 1,5 / 20
Cable Section 400 III + N +
T / Fuse
Nº x mm2 / A
5 x 1,5 / 20
5 x 1,5 / 20
5 x 1,5 / 20
5 x 1,5 / 20
5 x 1,5 / 20
5 x 1,5 / 20
DS/DL-28D
DS/DL-35D
STANDARD
EXCELLENCE
STANDARD
EXCELLENCE
Voltage and Standard Wiring
V
230I(CG,CV)-
400VIII+N+G(CE)
230I(CG,CV)-
400VIII+N+G(CE)
230I(CG,CV)-
400VIII+N+G(CE)
230I(CG,CV)-
400VIII+N+G(CE)
Frequency
Hz
50 / 60 (4)
50 / 60 (4)
50 / 60 (4)
50 / 60 (4)
Electrical
Heating
Cable Section 230 I + T/
Fuse
Nº x mm2 / A
-
-
-
-
Cable Section 230 III +
/Fuse
Nº x mm2 / A
4 x 35 / 100
4 x 50 / 125
4 x 50 / 125
4 x 50 / 125
Cable Section 400 III + N +
T / Fuse
Nº x mm2 / A
5 x 16 / 63
5 x 16 / 63
5 x 16 / 63
5 x 16 / 63
Gas or Steam
Heating
Cable Section 230 I + T
/Fuse
Nº x mm2 / A
3 x 1,5 / 20
3 x 1,5 / 20
3 x 1,5 / 20
3 x 1,5 / 20
Cable Section 230 III +
/Fuse
Nº x mm2 / A
4 x 1,5 / 20
4 x 1,5 / 20
4 x 1,5 / 20
4 x 1,5 / 20
Cable Section 400 III + N +
T / Fuse
Nº x mm2 / A
5 x 1,5 / 20
5 x 1,5 / 20
5 x 1,5 / 20
5 x 1,5 / 20