EasyManua.ls Logo

Prodys Quantum ST - IV.5.1.5. Battery; IV.5.1.6. Audio

Default Icon
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Prodys S.L. Tel: +34 91 6896880 Fax: +34 91 6943777 Email: sales@prodys.net Web: www.prodys.com
Page 90
Low Free space: Active when free space is <= 10% of the capacity of the
selected memory device.
Upload Failed: Active when the upload process fails.
AutoRec Tx Storage Not Ready: Active if "Automatically record input
signal when call connected” option is selected in Files->Rec menu and the
selected memory device is not available.
AutoRec Rx Storage Not Ready: Active if "Automatically record incoming
stream when call connected” option is selected in Files->Rec menu and the
selected memory device is not available.
Upload Can’t Connect: Active if the upload destination device is not
available.
Download Failed: Active if the download process fails.
Download Can’t Connect: Active if the communication with the server or
the remote Quantum device from which the files have to be downloaded is
not possible.
IV.5.1.5. Battery
Internal Battery Low: Active when the battery is not charging and the
charge percentage is <= 20%.
IV.5.1.6. Audio
Program (Codec 1) decoder framed lost: Active when a decoder loses
synchronization and also when the codec is powered off. The alarm will show
date and hour of the synchronization loss. The alarm will be maintained

Table of Contents