24 © 2008 by Proceq SA
4.5 Audio Setting
The device can give an audible tone when a key is
pressed, to assist in location or to give an alarm
when minimum cover alert is activated.
- No audio signals, silent
Centre Key pressed. Tone when rebar is centered. Minimum
cover alert.
Locate Key pressed. Increasing tone as approaching rebar.
Minimum cover alert.
4.6 Minimum Cover
If a minimum cover is selected, the LED is lit when
the cover is below this limit. If audio is on, an audio
signal is given.
Metric,
ASTM mm,
Japanese
ASTM
inch
- mm - inch
5 mm 0.20 inch
6 mm 0.24 inch
7 mm 0.28 inch
... ...
179 mm 7.04 inch
180 mm 7.08 inch
4.7 Neighboring Bar Compensation
Cover and bar diameter measurements are influ-
enced by neighboring bars. This can be compen-
sated by selecting the bar spacing.
Metric,
ASTM mm,
Japanese
ASTM
inch
- mm - inch
50 mm 2.0 inch
60 mm 2.4 inch
70 mm 2.8 inch
80 mm 3.2 inch
90 mm 3.6 inch
100 mm 4.0 inch
110 mm 4.4 inch
120 mm 4.8 inch
130 mm 5.2 inch
General Settings