Profound reserves the right to revise this documentation or to make improvements
or changes in the product(s) at any time.
VIBRA
VIBRA-sbr
VIBRA
+
Profound VIBRA-series: detailed features overview VIBRA VIBRA-sbr
VIBRA
+
Trace option Velocity versus time curve
● ● ●
AD-converter 24 bits delta sigma data conversion
● ● ●
Resolution display 0.01 mm/s
● ● ●
Resolution AD-converter 0.001 mm/s
● ● ●
Accuracy DIN 45669-1 June 1995, accuracy class 1
● ● ●
Frequency characteristic Lower limit (-3dB): 0.8 Hz (12 dB/oct.)
Upper limit (-3dB): 100 Hz (12 dB/oct.)
●
●
Zero crossing method
●
● Dominant frequency
determination
FFT (Hanning window)
●
DIN 4150-2
●
DIN
Data processing
DIN 4150-3
●
●
Accuracy Part A and B, 2002
0.85 ≤ Δ ≤ 1.15
● ●
Frequency characteristic Part A: Lower limit (-3 dB): 0.8 Hz
Upper limit (-3 dB): 125 Hz
Part B: Lower limit (-3 dB): 0.8 Hz
Upper limit (-3 dB): 100 Hz
● ●
Dominant frequency
determination
Method I
Method II
● ●
SBR
Data processing SBR Part A
SBR Part B
● ●
Sample frequency 1024 Hz
● ● ●
Velocity data save level Adjustable between 0.01-100 mm/s (or always)
● ● ●
Alarm level Adjustable between 0.01-100 mm/s (or none)
● ● ●
Clock stability
≈ 5 minutes/year at 25°C
● ● ●
Smart alarm level Frequency dependent maximum velocity,
complying with the SBR or DIN levels
●
Optical signal device Flashing alarm beacon (via USB cable)
● ● ●
External power
5 Volt supplied to the VIBRA USB connector
● ● ●
GSM/GPRS/internet mail function Wireless data transmission
●
Maximum displacement / u /
u
x
u
y
u
z
per time interval
●
VIBRA PC Trace Recorder Continuous time/velocity trace recording
●
Digital ID
● ● ●
Geophone detection
● ● ●
Digital correction of the sensitivity
● ● ●
Digital correction of the f
res
and Q
● ●
Automatic inclination check
●
VIBRA Geophone
Automatic calibration check
●
Windows 2000/XP
● ● ●
Processing according to SBR-guidelines
● ●
Processing according to DIN-guidelines
●
●
PC software
Extensive graphical data presentation including
precise date time axis. Various data exporting
options, e.g. as ASCII-(*.csv) file
● ● ●
P.O. Box 469 Tel. + 31 182 - 640 964
2740 AL Waddinxveen info@profound.nl
The Netherlands www.profound.nl
VIB010/11/2007
Profound Vibration Monitoring