19
Parameters | Sectors
User Manual | Agrónic 2500
The sectors are the outputs where the irrigation valves
are connected. They are related to pumps and the ir-
rigation meter. The history stores the irrigation and
fertilizing that each sector totals. The Agrónic 2500 can
manage up to 30 sectors.
SECTOR PARAMETERS
Sector: 01
Sector: 01
Pump 1: yes
Pump 2: no
Sector: 01
Waterhammer
temporization: +028 “
Meter: yes
Planned flow: 015.50 m3/h
Sector (00 ... 30): sector number to be configured. The
output of the sector is linked to the sector number,
sector 1 with R1, sector 2 with R2, etc. There is an
exception when the Agrónic has AgroBee-L.
5.5. SECTORS
Pump 1 and 2 (No | Yes): yes if the sector requires pump
1 and/or 2 to be activated to irrigate.
Waterhammer timing (-127 ... 000 ... +127”): time in
seconds of delay between the opening and closing of
consecutive and general sectors.
• With positive values, the valve opens immediate-
ly when irrigation starts and stays open for the
number of seconds programmed when it ends.
• With negative values, the opening is delayed for
the number of seconds programmed and when ir-
rigation ends, it closes immediately. There may be
an exception if the sector is the last of an irrigation
sequence and the pump stopping timer is applied.
Meter (No | Yes): yes if the sector will use the irrigation
meter.
Planned flow (000.00 ... 655.00 m3/h): it is the flow
consumed by the sector through drip emitters, sprin-
klers, etc. It is used to distribute the irrigation and
fertilizing volumes in the histories and totals of the
sectors that irrigate at the same time.
Start/Stop a generator set
AgroBee or AgroBee-L option
With this option, the sector valves can communicate
remotely via radio, so that you can configure in the
sector which output the valve will be connected to.
It also enables an auxiliary output that can be common
with other sectors. Activated whenever any of the
sectors that have it configured are activated.
SECTOR PARAMETERS
Sector: 01
N. of output: 00000
N. of output: 00000
The first question about output number corresponds
to the sector and the second to the auxiliary output.
To configure AgroBee or AgroBee-L outputs, see the
table in section ‘6. Input and output coding’.
Video tutorial
available for