21
Parameters | Installer
User Manual | Agrónic 2500
This section shows the least-common parameters to
change once the unit has been installed.
The input to this section is protected with an access
code that, if needed, must be requested from Progrés.
INSTALLER PARAMETERS
1. Erasure
2. Events
3. Access codes
4. Activate options
5. Various
6. Communications
7. Language
8. Update soware
9. Backup param.
5.6.1 Erasure
Totally erase the memory, RAM, records, programs and
sectors, etc.
5.6.2 Events
It is not possible to make modifications in the basic
version.
5.6.3 Access codes
Enables the limited access to the Parameters, Functions
or Erase Totals sections. Enter the 4-digit access code
here. Leave the value at 0 if this is not necessary.
5.6.4 Activate options
Used to activate or deactivate options once they have
been installed on the unit. To activate them, enter the
code provided by Progrés, and to deactivate them,
enter an erroneous code. The activated option will
display a ‘ * ’ to the right of the text for the option.
5.6.5 Various
Programs
• Sector limit (0 ... 8): only the sectors indicated
at the base of the Agrónic can be irrigated at the
same time. If more sectors are to be irrigated, they
are postponed until another one finishes. It is used
so that there is no consumption overload in the
output transformer.
• Sensor limit in program (0 ... 4): 1 to 4 sectors can
5.7. INSTALLER
be activated in each irrigation program. Here
you configure how many sectors are asked in the
program.
• Alternating sequential (No | Yes): when you want
a program sequence to not always start with the
same one.
Example
If program 1, 2 and 3 are linked, the first time
it starts with program 1, the second time with
program 2 and so on repeatedly.
• Sequential with 99:00? (No | Yes):
‒ Yes: to be able to indicate that one program is
sequential to another in the start time.
Example
To indicate that the program is sequential from
2, enter 99:02.
• In volume irrigation, ask for time (No | Yes):
‒ Yes: to set a maximum irrigation time when the
units are configured by volume. This time is
given for safety.
• Active schedule (No | Yes):
‒ Yes: it will ask the active schedule in ‘Function
- 1. Program’.
• Active period (No | Yes):
‒ Yes: it will request the active period in ‘Function
- 1. Program’.
• Activations (No | Yes):
‒ Yes: it will ask in ‘Function – 1. Program’ for ac-
tivations.
• Outside of active hours, end irrigation (No ... Yes):
‒ yes: if the program reaches the end of the active
schedule and has not finished, it continues with
irrigation.
‒ No: if the program reaches the end of the active
schedule and has not finished, irrigation stops.
Video tutorial
available for
this section