Type Pump capacity
at maximum back pressure
Pump capacity
at medium back pressure
Con‐
nector
size
outer Æ
x inner
Æ
Suction
lift*
Priming
lift**
Max.
priming
pres‐
sure on
the suc‐
tion
side
2
bar l/h ml/
stroke
bar l/h ml/
stroke
mm m water
column
m water
column
bar
0232 2 32.0 2.96 1.0 36.2 3.35 12x9 2.0 2.0 1
Metering pumps with self-degassing dosing head SEK***
1601 16 0.59 0.055 8.0 0.80 0.072 6x4 6.0 2.0 8
1001 10 0.72 0.067 5.0 0.60 0.08 6x4 6.0 2.0 5
0701 7 0.84 0.078 3.5 1.12 0.10 6x4 6.0 2.0 3.5
0401 4 0.9 0.083 2.0 1.2 0.11 6x4 6.0 2.0 2
2002 20 0.78 0.07 10.0 1.8 0.17 6x4 6.0 2.5 10
1602 16 1.40 0.13 8.0 1.70 0.16 6x4 6.0 2.5 8
1002 10 1.7 0.16 5.0 2.0 0.18 6x4 6.0 2.5 5
0702 7 1.8 0.17 3.5 2.2 0.20 6x4 6.0 2.5 3.5
0402 4 2.1 0.19 2.0 2.5 0.23 6x4 6.0 2.5 2
1604 16 2.7 0.25 8.0 3.6 0.33 6x4 6.0 3.0 8
1004 10 3.3 0.30 5.0 3.9 0.36 6x4 6.0 3.0 5
0704 7 3.6 0.33 3.5 4.0 0.37 6x4 6.0 3.0 3.5
0404 4 3.9 0.36 2.0 4.2 0.39 6x4 6.0 3.0 2
0708 7 6.60 0.61 3.5 7.50 0.69 8x5 6.0 2.0 3.5
0408 4 7.5 0.64 2.0 8.1 0.77 8x5 6.0 2.0 2
0413 4 10.8 1.0 2.0 12.6 1.17 8x5 6.0 2.5 2
0220 2 16.2 1.5 1.0 18.0 1.67 12x9 6.0 2.0 1
1008 10 6.3 0.58 5.0 7.5 0.69 8x5 6.0 3.0 5
0713 7 10.5 0.94 3.5 12.3 1.14 8x5 6.0 2.5 3.5
0420 4 15.6 1.44 2.0 17.4 1.61 12x9 6.0 2.5 2
Metering pumps with self-degassing dosing head SER****
1602 10 1.40 0.13 8.0 1.70 0.174 6x4 6.0 1.8 5
1604 10 2.7 0.25 8.0 3.6 0.33 6x4 6.0 1.8 5
0708 7 6.60 0.61 3.5 7.50 0.69 8x5 4.0 1.8 3.5
0413 4 10.8 1.0 2.0 12.6 1.17 8x5 5.0 1.8 2
0220 2 16.2 1.5 1.0 18.0 1.67 12x9 2.0 2.0 1
1008 10 6.3 0.58 5.0 7.5 0.69 8x5 3.0 1.8 5
2
The pressure on the discharge side needs to be at least 1.5 bar higher than the pressure on the suction
side. We therefore recommend installing a back pressure valve on the discharge side to adjust the
increased pressure. This will avoid excess pumping.