0
0.5
1
1.5
0
0.5
1
1.5
2
2.5
3
0 10 20 30 40 50 60 70 80 90 100
180 min
-1
90 min
-1
72 min
-1
54 min
-1
36 min
-1
18 min
-1
162 min
-1
144 min
-1
126 min
-1
108 min
-1
100
f [%]
90
80
70
60
50
40
30
20
10
C [l/h]
BT4b 1602
s [%]
p [bar]
k
A
B
1 2 4 6 8 11 13 16
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
0 10 20 30 40 50 60 70 80 90 100
180 min
-1
90 min
-1
72 min
-1
54 min
-1
36 min
-1
18 min
-1
162 min
-1
144 min
-1
126 min
-1
108 min
-1
100
f [%]
90
80
70
60
50
40
30
20
10
C [l/h]
BT4b 0701
s [%]
A
0
0.2
0.4
0.6
0.8
1
1.2
1.4
p [bar]
k
B
1 2
4
6 8 10
0
0.2
0.4
0.6
0.8
1
1.2
1.4
p [bar]
k
B
1 2
3.5
4 6 7
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
0 10 20 30 40 50 60 70 80 90 100
180 min
-1
90 min
-1
72 min
-1
54 min
-1
36 min
-1
18 min
-1
162 min
-1
144 min
-1
126 min
-1
108 min
-1
100
f [%]
90
80
70
60
50
40
30
20
10
C [l/h]
BT4b 1001
s [%]
A
0
0.5
1.0
1.5
2.0
2.5
0 10 20 30 40 50 60 70 80 90 100
180 min
-1
90 min
-1
72 min
-1
54 min
-1
36 min
-1
18 min
-1
162 min
-1
144 min
-1
126 min
-1
108 min
-1
100
f [%]
90
80
70
60
50
40
30
20
10
C [l/h]
BT4b 0401
s [%]
A
0
0.2
0.4
0.6
0.8
1
1.2
1 4
p [bar]
k
B
2
3
Fig. 27: A) Capacity C at medium back pressure depending on the stroke length s for different stroke rates f.
B) Associated correction factors k depending on the back pressure p.
Diagrams for setting the capacity
71

Table of Contents