Diaphragm Motor-Driven Metering Pump
Sigma/ 2 Control Type S2Ca
Operating instructions
PK_2_115
Two sets of operating instructions are required for the safe, correct and proper operation of the metering pumps: The
product-specific operating instructions and the "General Operating Instructions for ProMinent
®
motor-driven metering
pumps and hydraulic accessories".
Both sets of operating instructions are only valid when read together.
Original Operating Instructions (2006/42/EC)Part no. 985894 BA SI 040 05/11 EN
Please carefully read these operating instructions before use! · Do not discard!
The operator shall be liable for any damage caused by installation or operating errors!
Technical changes reserved.

Table of Contents

Questions and Answers

  • K
    Kent Bolton Jr.Sep 10, 2025
    What to do if the red LED indicator illuminates with “Error” and “FAN” flashing on my ProMinent Sigma 2 S2Ca?
    • M
      Margaret JohnsonSep 10, 2025
      If the red LED indicator illuminates and the identifiers “Error” and “FAN” flash on the display of your ProMinent Water Pump, there is an error in connection with the fan in the pump housing. Check the fan and replace it if necessary. Press the [P] key to reset.
  • E
    Eric PhillipsSep 12, 2025
    What does it mean if the red LED indicator illuminates with “Error” and “MEM” flashing on my ProMinent Sigma 2 S2Ca Water Pump?
    • S
      Shane MillerSep 12, 2025
      If the red LED indicator illuminates and the identifiers “Error” and “MEM” flash on the display of your ProMinent Water Pump, a stroke memory overflow has occurred. Eliminate the cause and press the [P] key, keeping in mind the consequences for your process.
  • T
    Teresa JordanSep 14, 2025
    Why is the green LED indicator illuminating on my ProMinent Sigma 2 S2Ca?
    • J
      jenniferfordSep 14, 2025
      If the green LED indicator illuminates on your ProMinent Water Pump, the liquid level in the storage tank has reached the "liquid level low 1st stage". Fill the storage tank.
  • B
    bryantshawnSep 16, 2025
    What does it mean if the green LED indicator illuminates and “Calib” flashes on my ProMinent Sigma 2 S2Ca?
    • K
      Kyle BlankenshipSep 16, 2025
      If the green LED indicator illuminates and the identifier “Calib” flashes on your ProMinent Water Pump, the pump is calibrated and the stroke length varies by more than ±10 scale divisions from the value at the time of the calibration. Reset the stroke length or recalibrate the pump at the desired stroke length.