8.3.5 Install new blower (Version FG 205 and FG 206)
1. Insert new blower or slide sheet metal hood over the blower:
Step one Step two
Step three
2. Notice the installation position. The pins must be in the position shown in the photo. The
solenoid would be to the left of the photo (notice graphics).
3. Screw the new blower with the hood.
Note: Do not forget the washer and gasket!