Page 60 of 69
Proton Products InteliSENS DG2030 Diameter Gauge Instruction Manual (Issue 1a)
INPUT PARAMETERS
DW Bit Comments Unit Range/Remark Default value
DW0 System Mode
0
Measurement Mode
0=Solid;1=Glass;2=Heli
x;
0
1
2
3 Unit 0=Metric;1=Imperial 0
4 Shrinkage mode 0=Percentage;1=Abs 0
5 SMFD tolerance mode 0=ABS;1=Percentage 0
6 SMFD interval mode 0=Time;1=Length; 0
7
DW1
DW2
Preset average diameter 1=0.01um/0.01mil 0~20000000 1000000
DW3
DW4
Preset X diameter 1=0.01um/0.01mil 0~20000000 1000000
DW5
DW6
Preset Y diameter 1=0.01um/0.01mil 0~20000000 1000000
DW7
DW8
Preset Z diamter 1=0.01um/0.01mil 0~20000000 1000000
DW9
DW10
Preset Ovality 1=0.01um/0.01mil 0~20000000 0
DW11
DW12
Preset average upper limit 1=0.01um/0.01mil 0~20000000 50000
DW13
DW14
Preset average lower limit 1=0.01um/0.01mil 0~20000000 50000
DW15
DW16
Preset X upper limit 1=0.01um/0.01mil 0~20000000 50000
DW17
DW18
Preset X lower limit 1=0.01um/0.01mil 0~20000000 50000
DW19
DW20
Preset Y upper limit 1=0.01um/0.01mil 0~20000000 50000
DW21
DW22
Preset Y lower limit 1=0.01um/0.01mil 0~20000000 50000
DW23
DW24 Preset Z upper limit 1=0.01um/0.01mil 0~20000000 50000

Table of Contents