Lists the applied standards such as ETSI EN 300 328, EN 61326, EN 61010, EN 60950.
Details the products covered by the declaration, including PD30 and SiDi-CDi4 with part numbers.
Provides Proton Products International Limited's address and ISO9001:2015 registration status.
Introduces the InteliSENS PD30 gauge, its capabilities, and optional CDI4 display unit.
Details technical specifications of the PD30 gauge, including scan rate, diameter, accuracy, and environmental protection.
Lists standard interfaces like digital inputs, relay outputs, analogue inputs, and communication interfaces.
Describes optional interfaces such as analogue outputs, WiFi, Profibus, Profinet, and EtherNet/IP.
Outlines optional functions like PI feedback controller, Statistics, FFT, and SMFD.
Provides labelled diagrams of the gauge head and its connectors, identifying components.
Details the designation, connector type, and description for each interface port on the gauge.
Describes optional communication interfaces like WiFi, Profibus, Profinet, and EtherNet/IP, with part numbers.
Details optional electrical interfaces such as analogue outputs, PI feedback controller, and optional firmware.
Explains optional firmware functions like FFT analysis and SPC control, and their requirements.
Covers safety and handling precautions, including operating temperature, impact protection, and optical window care.
Outlines the step-by-step procedure for mechanical and electrical installation of the gauge.
Provides details on mounting the gauge, including dimensions and alignment notes.
Describes earth connection requirements and the use of shielded cables for signal connections.
Explains power supply voltage, consumption, connection methods, and powering on the gauge.
Describes the initial Proton welcome screen displayed when the gauge powers on.
Details the information displayed on the four Home Pages of the CDI4 interface.
Shows the main function menu icons for accessing various configuration and information pages.
Explains how to set preset diameter, tolerances, and shrinkage modes via the CDI4 interface.
Covers setting measurement modes, units, resolution, and averaging times within the CDI4 interface.
Describes the standard CAN-bus interface, its operation, and LED indicator status.
Details the RS-232 interface, its connection, baud rates, and SLP protocol.
Explains the RS-422/RS-485 interface, its connection, and two-wire operation.
Covers the standard Ethernet interface, its connection via RJ45, and LED indicator status.
Describes optional WiFi, Profibus, Profinet, and EtherNet/IP interfaces and their LED indicators.
Details optional analogue outputs, their configuration, and electrical specifications.
Explains the optional PI feedback controller, its connection, and electrical specifications.
Provides a detailed pinout diagram and functional description for the DB25 interface connector.
Describes the protocol for accessing gauge parameters via RS-232, including data formats and commands.
Explains the Modbus protocol for instrument communication, including frame format and supported functions.
Lists and explains the gauge's input parameters (DW0-DW129), their ranges, and default values.
Lists and explains the gauge's output parameters (DW0-DW50), their units, and range/remarks.
Provides contact information for different regional offices and service inquiries.