SUPA8 User Manual
10
SUPA8 Indicator Lights
Listed below are the use of the indicator lights when in normal operation.
Keypad
Light
Light ON Light OFF Light Flashing
On-Line
Dialler on line Dialler not on line Dialler had problems
Low Batt
Battery Charge Voltage Low Battery OK Had Low Batt alarm
AC Fail
Power not connected Power OK Had AC fail alarm
On
SUPA8 is ON (Away mode) SUPA8 is OFF SUPA8 is ON (Home
mode)
Zone 1 - 8
Unsealed, Manual or Auto
isolated
Zone is sealed Had alarm
Note that the status of the Zones will always be displayed unless disabled
by the installer. The Low Batt and AC Fail lights will show the current
state of these inputs, however the alarm (or restore) condition may have to
be present for a period before a report is initiated.
If the dialler fails to communicate, the On-Line light will remain flashing
until the next time the system is turned OFF.
All Zone lights on plus a continuous beeper
Means the keypad is locked out for 60 seconds caused by 4 consecutive
incorrect code entries.
All Zone lights flashing
Indicates a legal code has been entered (or the # key pressed) and the
SUPA8 expects another key to be pressed to select the desired function
within 10 seconds.
To cancel simply wait 10 seconds or press the
* key.
Keypad Beeper Operation
The keypad beeper will sound under the following circumstances: