Thank you for purchasing the SUPA8 Security Alarm System, the following is intended
to assist you in the installation of the system. Please read these guidelines before
installation.
Note: In some States of Australia special licensing may be required in order to
install Security Alarms and Associated Equipment. Please check with your
local State Authority for details before commencing installation work.
IMPORTANT:
This section is a brief outline of installation and programming. For additional
information refer to the SUPA8 Installer Manual.
Factory Defaults
THE SUPA8 ALARM SYSTEM COMES FROM THE FACTORY PROGRAMMED AND
READY TO GO. BEFORE MAKING ANY CHANGES, CHECK WHAT IS ALREADY
PROGRAMMED, AS THEY WILL MOST PROBABLY SUIT YOUR NEEDS.
MASTER USER CODE : 1 2 3 4
INSTALLER CODE : 2 5 8 0
ENTRY TIME : 30 seconds
EXIT TIME : 60 seconds
SIREN TIME : 5 minutes
ZONE TYPE Zone 1 : Entry Delay - enables entry exit timer.
Zone 2 : Handover - enables exit timer and entry timer
if Entry Delay Zone entered first.
Zone 3 : Handover - enables exit timer and entry timer
if Entry Delay Zone entered first.
Zone 4 : Instant - immediately sounds siren if violated
when system is armed.
Zone 5 : Instant - immediately sounds siren if violated
when system is armed.
Zone 6 : Instant – immediately sounds siren if violated
when system is armed.
Zone 7 : 24 Hour - sounds sirens if violated whether
system is armed or disarmed.
Zone 8 : 24 Hour - sounds sirens if violated whether
system is armed or disarmed.
NOTE: When Armed in Home Mode Zones 5 and 6 has been programmed to be
isolated.