SUPA8 Quick Setup
6
System is now operational as a Self Monitored Dialler.
Note: In the event of an alarm, the dialler will emit via the telephone system, a computer
generated siren tone.
If you are installing a Dialler Panel and do not wish to connect to a telephone line, you
MUST default the panel to a local format. (See page 7 of Installer Manual)
To Assign for Pinkerton Security Central Monitoring Station Dialling.
There are two formats that can be selected for central station monitoring; domestic monitoring and
business monitoring. The difference between domestic and business monitoring is that business
monitoring will send opening and closing reports.
Before commencing programming please contact Pinkerton Monitoring Pty Ltd on (03) 9888 9889
for allocation of Dialler Telephone Numbers and Client Identification Number.
Step 1: On Keypad
To enter programming mode.
Enter:
2580 7
You are now in Programming Mode (ON-LINE light will flash).
Enter: 250 3578 (for domestic monitoring)
or
250 4578 (for business monitoring)
Step 2: On Keypad
Re-enter programming mode:
Enter:
25807
Step 3:
On Keypad
To program Central Monitoring Station Telephone Number:
Enter:
128 0391234567 #6 *
Enter: 144 0391234567 #6 *
Note: (a) The above number 03 91234567 is an example only.
(b) If you are only supplied with one central station number please enter
that number into both telephone addresses.
(c)
#6 is used to finish the phone number.
(d)
* completes address (allows next address).