Programming Parameters
90 PT2000™ & TopGun™
Other Controls Enter 1 for On and 0 for Off.
Enable manual reset
B0 On/Off On or Off OnOnOn
Auto-Off
B2 Value 00–99
(minutes)
00 60 10
Intercharacter delay (keyboard
wedge only)
B3 Value 00–99
(milliseconds)
00 06 00
Add symbology identifiers
*
B5 On/Off On or Off Off On Off
Good-read tone
B8 Value 00 (low) – 07 (high) 05 05 05
Good-read number of beeps
B9 Value 01–04 01 01 01
Good-read tone duration
BA Value 00 = 0.14 sec.
01 = 0.07 sec.
02 = 0.45 sec.
03 = 0.22 sec.
01 01 01
Beeper volume
BC Value 00 = Off
01 (low) – 07 (high)
08 = One level higher
09 = One level lower
07 07 07
Error tone
BD Value 00 (low) – 07 (high) 03 03 03
Time format
D8 On/Off On = 24-hour
Off = 12-hour
On On On
Date format
D9 On/Off On = International
Off = U.S.
Off Off Off
Keyboard click
DD On/Off On or Off OnOnOn
Laser delay
DE Value 00–99
(10-millisecond units)
01 01 01
* A = UPC-A E = UPC-E K = Code 128
B = Interleaved 2 of 5 G = EAN-8 L = Code 93
C = Code 39 I = Codabar M = EAN-13
*.
Code Parameter ID # Type Acceptable Input
Predefined Defaults
D0 D1 D2
PT2000.book Page 90 Thursday, February 26, 2004 9:34 AM