Transferring Data With PSC Utilities
74 PT2000™ & TopGun™
3. By default, PTFER uses the following communications settings:
These are also the default settings for the PT2000 and TopGun.
Scan the following bar code to set the portables serial
communications parameters to these defaults:
To switch to a different port or make other changes to the
defaults, refer to “
Changing Settings,” on page 76.
4. Select Options >Connect (or click on the Connect button in
the
Communications Settings dialog box) to connect with the
selected port.
5. The message Communications port opened appears in the
window. It is now possible to transfer files between the PC and
the portable.
Uploading a File
To upload a file from the PT2000 or TopGun to the PC:
1. Select File > Receive and use the File to Receive dialog box
(refer to
Figure 5-2) to specify the name and location of the file to
store the data in.
Port
COM2
Baud rate
9600
Stop bits
1
Data bits
8
Parity
None
Protocol
ACK/NAK
Serial Communication
parameters (defaults)
*$+$-C8EE*
* $ + $ - C 8 E E *
PT2000.book Page 74 Thursday, February 26, 2004 9:34 AM