Enter HOLIDAY
CLOSE Time
PRESS # WHEN DONE
Sets the time of day on the next Holiday
that Relay 2 will deactivate.
Enter the Next
Holiday Date:
PRESS # WHEN DONE
Sets the next date that will use the holiday
hours.
Slave After Hours
ENABLED
Press * to Change
PRESS # WHEN DONE
Allows Relay 2 to activate when Relay 1 is
tripped outside of hold open hours. Useful
when using a secondary gate. Factory
default is Enabled.
Max. # of Attempts Before
Lock Out: 000
PRESS # WHEN DONE
Sets the maximum number of attempts
within a one minute period before the APEX
will prevent further code entry. If the number
is set to three, then after three successive
attempts with invalid codes, the user will be
locked out. The lockout remains active for
60 seconds after the last key press. If the
user keeps pressing keys the lockout time
will continue to be reset. The maximum
value is 10. Factory default is 000, which
disables the lockout feature.
Use Custom Message? NO
Press * to Change
PRESS # WHEN DONE
Displays a third message on the display
before any key is pressed. The APEX will
scroll through three messages instead of two
and allows communication with customers.
It cannot be changed from the controller.
Factory default is NO.
Trip Relay Ofine? NO
Press * to Change
PRESS # WHEN DONE
Causes Relay 1 to trip if the APEX is not
communicating with the controller.
WARNING: Improper use of this option
leave your site vulnerable. Do not set this
option on an entry keypad. Factory default
is NO.
Current Comm. Off
Time (seconds) 005
PRESS # WHEN DONE
Sets the amount of time the APEX
should wait before considering it has lost
communication with the controller. Any
value from 1 to 255 seconds can be entered.
Factory default is 5 seconds.
APEX Access Device
38