Testing the Keypad
1
Test the display by applying power to the keypad.
- The default date and time should appear on the display
after power is applied.
- The controller displays the date and time to the keypad
once a minute. The date and time on the display should
update if the keypad is configured correctly.
2
To verify that the backlight is working:
- Press the * key. The backlight should light up and the display
will read Please Enter Access Code.
- If no keys are pressed within 10 seconds, the display will
return to the Date/Time and the backlight will shut off.
3
To test touchpad operation:
- Press the * key. When the display shows
Please Enter Access Code, press
0, 1, 2, 3, 4, 5, 6, 7, 8, 9. Each digit should
appear on the display as it is pressed (if Secure Entry is
enabled a * for each digit appears on the display)
- Press the # key to transmit the code to the controller,
the display will show Please Wait until a response is
returned from the controller.
- If the keypad is communicating with the controller, the
display will show either Entry Granted or another
corresponding message.
APEX Access Device
23
rev. 7-2017 114A3863.E